Instrument Run
Covering NGS and third-generation sequencing (TGS), meeting every need from short to long reads and from bulk to single cell
Methodology note · content is citable as-is
- PE150 mode, read length up to 2×300 bp
- up to 25 B reads per flow cell
- Q30 ≥ 85% (WGS)
- supports WGS / WES / RNA-seq / scRNA-seq
01Sequencing Platforms
Covering NGS and third-generation sequencing (TGS), meeting every need from short to long reads and from bulk to single cell
Illumina NGS Platform
short reads · high throughput · high accuracy
Model
Illumina NovaSeq X Plus / NovaSeq 6000 / NextSeq 2000
Technical Highlights
- PE150 mode, read length up to 2×300 bp
- up to 25 B reads per flow cell
- Q30 ≥ 85% (WGS)
- supports WGS / WES / RNA-seq / scRNA-seq
Applicable Omics
genomics (WGS/WES), transcriptomics (RNA-seq), single-cell sequencing
PacBio TGS Platform
long reads · HiFi accuracy · direct methylation sequencing
Model
PacBio Revio / Sequel IIe
Technical Highlights
- HiFi reads: 15–25 kb average, >99.9% accuracy
- up to 90 Gb HiFi data per run
- direct DNA-methylation (5mC) detection
- ideal for complex-genome assembly and structural-variant detection
Applicable Omics
whole-genome sequencing (large genomes), full-length transcript sequencing, methylation sequencing
Oxford Nanopore Platform
ultra-long reads · real-time sequencing · direct methylation detection
Model
Oxford Nanopore PromethION 24 / MinION Mk1C
Technical Highlights
- ultra-long reads: 30–50 kb average, >1 Mb maximum
- PCR-free direct sequencing with reduced bias
- real-time data output—analyze while sequencing
- suited to metagenomics, viral assembly and structural variation
Applicable Omics
metagenome sequencing, large-genome assembly, viral-diversity research
02Mass-Spectrometry Platforms
Top-tier Thermo Fisher and Bruker MS systems covering high-precision proteomics and metabolomics detection
Thermo Orbitrap Astral
ultra-fast scanning · high sensitivity · 4D proteomics
Technical Highlights
- scan rate: up to 200 Hz (Astral mass analyzer)
- resolution: up to 480,000 FWHM (Orbitrap)
- >12,000 proteins identified per DIA run
- dynamic range: > 5 orders of magnitude
Applications
4D proteomics (DIA/DDA/PRM), PTM analysis, large-cohort clinical studies
Bruker timsTOF HT
ion-mobility separation · PASEF technology · ultra-high sensitivity
Technical Highlights
- mobility resolution: up to 300–500 1/K0
- PASEF mode improves ion utilization 10–20×
- scan rate: up to 100 Hz MS/MS
- suited to ultra-low sample loads (< 100 ng)场景
Applications
low-input proteomics, single-cell proteomics, deep plasma proteomics
Thermo Q Exactive HF-X
high resolution · accurate mass · for both metabolomics and proteomics
Technical Highlights
- resolution: up to 240,000 FWHM (@ m/z 200)
- mass accuracy: < 1 ppm(外标校准)
- dynamic range: > 4 orders of magnitude
- supports DDA / DIA / PRM acquisition modes
Applications
metabolomics (LC-MS/MS untargeted + targeted), proteomics (DIA/DDA), PTM analysis
03Standard Run Procedure
Standardized procedure from library/sample loading to data output
Run Preparation
library/sample QC recheck, flow-cell/column preparation
Pooling & Loading
libraries pooled at equimolar ratios, diluted and loaded onto the flow cell
Sequencing / Acquisition
run per preset protocol with real-time monitoring of Q30/resolution
Real-Time QC
data quality checked every 12–24 h; parameters adjusted as needed
Data Output
raw data (FASTQ/RAW/WIFF) transferred to storage servers
04Platform Parameter Comparison
| Platform | Read length / resolution | Throughput (per run) | Accuracy / mass accuracy | Run time |
|---|---|---|---|---|
| Illumina NovaSeq X Plus | PE 2×150 bp | up to 25 B reads | Q30 ≥ 85% | approx. 24–48 h |
| PacBio Revio | HiFi 15–25 kb | up to 90 Gb | accuracy > 99.9% | approx. 24 h |
| Nanopore PromethION | ultra-long reads 30–50 kb | up to 150 Gb | accuracy ~98% (HAC model) | real-time (interruptible) |
| Orbitrap Astral | resolution 480,000 | ~200 Hz scan rate | mass accuracy < 1 ppm | sample-dependent (hours) |
| timsTOF HT | mobility resolution ~400 | ~100 Hz MS/MS | mass accuracy < 1 ppm | sample-dependent (hours) |
05In-Run QC Monitoring
Key metrics monitored in real time during runs to ensure data meets delivery standards
Sequencing QC Metrics
Q30 ≥ 85%
NGS Q30 (error rate ≤ 0.1%) ratio; below 80% triggers an alert and re-run assessment.
- Coverage uniformity: per-sample coverage CV < 0.2
- Mapping rate: reference-genome mapping rate ≥ 70%
- Duplication rate: WGS duplication rate < 20%
MS QC Metrics
MS1 resolution ≥ 60,000
MS1 resolution ≥ 60,000 for proteomics DIA; ≥ 35,000 for metabolomics.
- Retention-time drift: within batch < 1 秒
- QC-sample RSD: metabolite peak-area RSD < 15%
- Identifications: HeLa DIA single injection > 8,000 proteins
Alert & Response Mechanism
real-time monitoring · rapid response
QC reports are generated every 12 hours during runs; technicians act on the following rules:
- Yellow alert: Q30 drop within 3%—continue running with enhanced monitoring
- Orange alert: Q30 < 80% 或 QC RSD > 20%—pause and assess
- Red alert: severe deviation—terminate the run, troubleshoot and re-run
06Pre-Run Checklist
Pre-run checklist for sequencing samples
- library concentration ≥ 2 nM (Illumina standard); use EB buffer when diluting to working concentration
- library fragment distribution as expected (Agilent TapeStation), no significant adapter-dimer peaks
- libraries pooled at equimolar ratios to avoid over-representation of any sample
- clustering-efficiency forecast: expected reads per sample matching the study design
- flow-cell model matched to library type (NovaSeq X Plus uses X-series flow cells)
Pre-run checklist for MS samples
- protein/metabolite extracts fully depleted of host proteins/salts (lines flushed with LC-MS-grade water/acetonitrile)
- column equilibrated ≥ 30 min; retention-time stability RSD < 1%
- pooled QC prepared and pre-injected ≥ 5 times until the system stabilizes
- mass axis calibrated (external calibration; mass deviation < 1 ppm)
- injection order randomized to avoid batch effects on quantification